When protecting sensitive information is critical to your success, the
OSCOR provides the most automatic, reliable and cost effective capability on
the market.
OSCOR is a complete eavesdropping
detection package that is portable and programmable. OSCOR is a microprocessor
controlled countersurveillance system with a custom designed built-in spectrum
analyzer that can operate automatically storing all encountered signals in
memory for later review. Designed to detect all major types of audio and video
RF transmitters, including carrier current and infrared. OSCOR is the only
product that protects your environment 24 hours a day. Features Automatic
Threat Correlation.
The patented OSCOR correlator
provides signal classification by correlating the demodulated audio of a
received signal to the ambient noises of an environment. Automatic Signal
Scanning and Logging.
Only the OSCOR provides an automatic
solution to rapidly logging and classifying all the signals of your
environment. A quick reference guide provides a single chart that completely
defines the programming process. Sonic ranging and triangulation to pinpoint
bug locations. Using the Patented Threat Locating System, a bugging device can
be readily found with no destructive searches.
The Triangulate and Locate option
uses sonic ranging to locate a threatening microphone. The OSCOR provides
detailed signal analysis capabilities with a complete built-in suite of audio
demodulators and IF bandwidth selections.
The audio demodulators include FM
wideband, FM narrowband, AM wideband, AM narrowband, Sub-carrier, Single
Sideband, and IF bandwidths 250 kHz, 15 kHz, and 6 kHz. Built-in video monitors
display images received on transmitted signals for protection against covert
video transmitters.
Supported video formats include
NTSC, PAL, and SECAM. This feature is not included in the basic unit. Built-in
automatically switched antenna array. Foldout antenna panel automatically selects
the proper antenna with no connections required. Pre-amp provides maximum
sensitivity for the proper input. No un-reliable cable connections or
mismatched antenna inputs. Built-in printer for hard-copy printouts.
The OSCOR built-in thermal printer
provides a user with the ability to generate printouts of important sweep data.
Removable Program chip for ease of upgrading software. When a new OSCOR upgrade
comes out, simply contact REI to request a new program key. PC Interface and
Remote Control of the OSCOR. The OSCOR PC interface software provides the
capability to create permanent database profiles of sweep environments,
generate professional reports and graphs.
- Standard
Package OTL-5000 OSCOR Triangulate and Locate: This option utilizes a patented
ranging process (REI maintains exclusive patent rights to Glenn Whidden’s
patent # 4,399,556) to triangulate on the location of an eavesdropping device.
Does not require return to REI for installation.
- OVM-5000
OSCOR Video Option (Multiple formats): Allows the OSCOR to provide viewing of
video signals. Used for detection of covert surveillance cameras. Supports
NTSC, PAL and SECAM. Includes a video demodulator circuit board that must be
installed in the OSCOR main unit and two video monitors that fit inside the
OSCOR storage Compartment. Includes OVP-5000.
- OVP-5000
OSCOR Video Patch Cord: Patch cord that allows received video signals to be fed
directly into an alternate video monitor or a video recorder. Video output is
provided in a standard RCA plug.
- OAR-5000
OSCOR Audio Recorder and Cables: Audio micro-cassette recorder that connects
directly into the connector tray to use the OSCOR audio recorder functions.
OEM-5000 OSCOR Extra Memory (512K): Increases the OSCOR signal storage
capability from 7,168 signals to 28,672.
- LPE-5000
Locator Probe Extension Cable: BNC cable that is identical to the locator probe
cable. Comes with barrel connector and provides extension for the Locator Probe.
MIC-5000 Miniature Microphone: Used with the standard OSCOR cables to provide a
remote microphone input.
- MPC-5000 OSCOR Multiple Purpose Cable: 12’
Cable with 3.5mm male and 3.5mm female connectors. Used to extend Loop Antenna
range, OSCOR Telephone Coupler and options MIC-5000.
- MPA-700
Modular Phone Adapter: Provides easy access to telephone conductors for
testing. Universal connector works for 2,4,6 & 8 conductor telephone
systems. CLA-700 Cigarette
Lighter
Adapter: Provides DC input to power the OSCOR from an automobile cigarette
lighter.
- Additional
Options OIF - OSCOR IF interface: An external RF port for the OSCOR. It
provides an output from the 10.7MHz Intermediate Frequency in the OSCOR. Using
the OIF port, a signal can be fed from the OSCOR into other types of test
equipment to further analyze the signal. The signal could be fed into an
external spectrum analyzer that may have digital demodulation capabilities (but
not the frequency range of the OSCOR), an oscilloscope for further time-domain
analysis, or into an analog CRT type display.
- OBB
- OSCOR Base Band option: Similar to the OIF, this is also an RF external
output. However, it is taking the signal directly out of the demodulator
circuit. The bandwidth of this option is 250 kHz and is primarily used to feed
a signal into an oscilloscope and perform an FFT Frequency spectrum analysis.
In this manner, the user can see any sub-carrier type signals in the frequency
display. The OSCOR provides the ability to see sub-carriers, but this option
provides a better capability.
OSC-5000 Advantages Portable
complete package of counter surveillance test equipment. Complete unit is the
size of a large brief case and can be easily carried on a plane, bus, or car as
hand-carry luggage.
Programmable Automatic Mode that
continuously scans all bands and silently detects eavesdropping devices. The
OSCOR can be used around the clock to monitor an environment without an
operator present. Signal Database Storage provides ability to store, retrieve,
and analyze signals that are automatically logged by the OSCOR.
New software will provide the
ability to develop signal databases for each sweep location as well as
performing future signal comparisons. High Sensitivity Digital Synthesized
Receiver scans Radio Frequency (10KHz to 3GHz),(3-21GHz by using the MDC-2100
down converter), carrier current (10KHz to 5 MHz) including and infrared (850nm
to 1070nm / 10KHz to 5 MHz).
· Built-in
Demodulators and Bandwidths: Demodulators include AM, FM, SSB, Sub-carrier, and
video(available as an option). IF bandwidths are built-in and programmable and
include 6Khz, 15KHz, and 250Khz.
· Antenna
Array: All OSCOR input antenna's are built into the case and are automatically
switched. Acoustic Correlator utilizes passive sound pattern matching to automatically
detect and classify a listening device even when the OSCOR is running
automatically (un-manned).
· Strip
Chart Plotter built-in the OSCOR to provide hard-copies of spectrum profiles,
signal database information, correlation printouts, etc..
· Printer
functions as WYSIWYG(What You See Is What You Get) operation by printing any
information that is displayed on the screen.
· Video
Receive and Display Capability.
· Optional
feature provides ability to receive NTSC, PAL, and SECAM video formats to
provide detection of transmitted video signals including covert chip cameras
that are increasingly proliferated.
· Triangulation
and Location System*. Patented system that allows the user to pin-point the
location of an eavesdropping device without the need for destructive and time
consuming searches.
· Computer Interface to provide signal database
utilities and remote control of the OSCOR.
*New optional Capabilities.
OSC-5000 Advancements Specifications
RF System:
- RF
Receiver
- Type:
Quad Conversion Super Heterodyne with 3 phase locked loop synthesizers RF
Frequency
- Coverage:
10kHz-3GHz
- Tuning
Resolution: 100Hz
- Sensitivity:
0.8µV typical with 15kHz
- Bandwidth
(+15dBm MAX) Demodulators: AM, FM Wide, FM Narrow. FM SC, SSB/CW IF
- Bandwidth:
250kHz, 15kHz, 6kHz
- Attenuators:
0, -20dB at active whip, Discone, and VLF-MF input
- Dynamic Range: 90dB Subcarrier
- Tuning
Range: 15kHz-250kHz
- Antenna
Types: Balanced Loop 10kHz-500kHz (35-45kHz Narrow)
- Active
Whip: 500kHz-1500MHz
- Discone:
1500MHz-3000MHz
- Infrared
Detector: 10kHz-5MHz, 850-1070nM
- AC
Carrier Current: 10kHz-5MHz (Balanced Across Power Line)
- Control
System: 8/16 Bit Microcontroller 128 (512K Optional)
- Static
RAM Memory Optical Encoder: 128 Pulse/Rev with variable count ratio
- Program
Key: 64K Byte ROM
- Display:
128 x 256 Segment Graphics Supertwist LCD
- Printer:
192 Dot Per Line Graphics on 2" wide thermal paper
- Audio
System: Frequency
- Response:
50Hz-15kHz
- Voiceband Filter: 300Hz-3000Hz -18dB/Octave
AGC
- Dynamic
Range: 60dB Output
- Power:
3W @ 4 Headphone
- Output:
0-2V rms @ 220
- Record
Output: 50mV rms (with AGC) @ 500
- Remote
contact: Normally Open (200mA 32V MAX)
- Balanced
Auxiliary Input: 0.5V rms Nominal @ 600
- Reference
Audio Input: 1mV - 1V rms @ 3.9K
- Sonic
Correlator: 50Hz - 15kHz (Frequency Independent)
- Audio Alarm: 3 Level Programmable Two Tone
Ringer
- Squelch:
Automatic digital or manual control over full display range
- Headphones:
Low acoustic leakage, output limited to 105dBA
- Power
System: AC
- Input:
105-130/210-260VAC, 50-60Hz, 24W
- External
DC Input: 12-l8VDC, 1A max
- Internal
Battery: 12.6V, 2.9 Ah 3 hour operation per charge typical
- Mechanical:
Size(HxWxD): 6.25 x 18.5 x 14.5 in (47 x 36.8 x 15.9 cm)
- Weight:
24 lb. (11 kg)
Upgrades and Accesories OPC-5000:
- OSCOR PC Interface Option NGA-5000
- Noise Generator for OPC OIF-5000
- IF Output (10.7 MHz) LAA-1530
- Log Active Antenna (1.5-3.0 GHz)
MDC-2100
- Microwave Down Converter. |